FM Transmitter Measurement Report
Created: 2022-01-06 18-28-43
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
99.00 MHz |
5/5, 83 dBuV |
FREQ 3 |
Pilot |
RDS |
Phase
Difference |
6.9 kHz |
4.4 kHz |
-85 deg |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
0,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 75,0
kHz |
15 kHz |
73 kHz |
11919 |
22,8375 |
|
Modulation Power
Limit |
Measuring
Tolerance |
9,0 dBr |
0,0 dBr |
MIN |
AVE |
MAX |
% above
9,0 dBr |
6,0 dBr |
7,19 dBr |
8,0 dBr |
0,0 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
" FREQ 3 " |
F536 |
10 (Pop M) |
1 |
0 |
1 |
3 |
18:28, 6.01.2022 |
RT |
"The Bangles -> Walk Like An Egyptian " |
AF |
EON |
89.9, 99.0 MHz |
- |
|
|